Description
Gas Clip Technologies Multi Gas Clip Simple MGC -S- Detects H2S, CO, O2 & Combustible Gases (LEL), 2 Year Run Time- No Charging Ever
Gas Detection Made Simple
Used with MGC-S-Dock Simple Docking Station
Gas Clip Technologies – Portable Gas Detection You Can Count On!
No charging ever! No calibration needed, but Can be Bump Tested & Calibrated as Needed per Job Requirement
Detects H2S, CO, O2 & combustible gases (LEL)
Save time never having to charge or service your portable multi-gas detector! Reliably test for H2S, CO, O2 & combustible gases (LEL)) with this simple-to-use & simple-to-maintain detector. Just turn it on & have worry free assurance of protection against toxic gases 24/7 for two full years.
Gas Clip Technologies’ continued development and refinement of advanced low-power photometric infrared technology for LEL measurement helps make gas detection simpler than ever in the newest member of their gas detector family – the Multi Gas Clip Simple. No charging ever. No calibrating needed. No Maintenance. It’s SIMPLE!
Features:
- 2 year runtime – 2 year life!
- No charging ever! No calibration needed- but Can be Bump Tested & Calibrated as Needed per Job Requirement
- Durable
- Ergonomic
- Simple One Button Operation
- Works in oxygen enriched and oxygen deficient environments
- LEL sensor is immune to H2S & silicone poison
- Full datalogging at 1 second intervals
- Assembled in USA
- Only Compatible with MGC Simple Dock or MGC Simple Wall Mount Dock
- Size 4.75” H x 2.75” W x 1.25” D (120.65 x 69.85 x 31.75 mm.)
- Weight 7.675 oz. (220.2 g)
- Temperature -40 to +122F (-40 to +50C)
- Humidity 5% to 95% RH (non-condensing)
- Battery Life 730 Days continuous (based on avg. of 1.5 min. of alarm/day)
- Alarms Visual, vibrating & audible (minimum 95 dB) Low, High, STEL, TWA & OL (Over Limit)
- LEDs 4 Red alarm bar LEDs Yellow back-light (activated on button press) Red back-light (activated on alarm condition) Yellow Maintenance Notification LED
- Display High viewing angle alphanumeric Liquid Crystal Display (LCD)
- Logs 25 Bump tests 25 Events 25 Calibrations Continuous 1 second data logging (typical capacity >2 months)
- Tests Full function self-test upon activation Sensors, battery and circuitry tests run continuously
- Ingress Protection IP 68
- Warranty Full 2 years
- Gases H2S 0 – 100 PPM (0.1 PPM increments) CO 0 – 500 PPM (1 PPM increments) Combustible (LEL) 0 – 100% LEL (0.1% increments) O2 0 – 30% vol. (0.1% increments) Sensor Type H2S, CO & O2 – Plug-in electrochemical cell Combustible (LEL) – Soldered infrared (IR)