Description
Gas Clip – MGC-IR-PUMP Multi Gas Clip 4 Gas Detector, Internal Pump & Infrared Combustible Sensor (H2S, CO, O2 & LEL)
PUMPED up multi gas detector with internal pump runs 52 hours continuously on a single charge
Features
- 52 hour continuous run time – Operates with pump on for 52 hours continuously
- Detects combustible gases (LEL), hydrogen sulfide (H2S), carbon monoxide (CO) & oxygen (O2)
- 1 year calibration cycle saves valuable time & test gas
- Will work in inert environments, no need for oxygen
- Powerful but quiet pump draws from up to 75 feet
- Stainless steel gas inlet
- Detects accurately in oxygen-depleted environments
- Low maintenance cost – infrared LEL sensor is immune to poisons
- Simple to use, one button operation – large, easy to read screen
- Lightweight & durable – alligator clip clamps on tight
Gas Clip – MGC-IR-PUMP Multi Gas Clip 4 Gas Detector Specifications
Weight | 352 g (12.4 oz) |
Temperature | -20 to 50°C (-0 to 122°F) |
Humidity | 5 to 100% RH non-condensing |
Alarms | Visual, Vibrating and Audible (minimum 95 db) Low, High, STEL, TWA and OL, Pump |
Tests | Full function self-test on activation and every 20 hours Continuous automatic battery and sensor tests |
Ratings | IP 67/ Complies with EMC directives 89/336/EEC |
Battery Life | 5 Days Continuous |
Gases | H2S: 0 to 100 PPM (0.1 PPM Increments) CO: 0 to 500 PPM (1 PPM Increments) Combustible Gas: 0 to 100% LEL (0.1% LEL Increments) O2: 0 to 30% vol. (0.1% vol. Increments) |
Calibrate the MGC Pump Once Every 12 Months
Other multi gas detectors require calibration anywhere from 1 to 3 months. The MGC Pump can go 12 months without being calibrated. This is an added benefit of IR sensing technology because IR is immune to pellistor sensor poisons such as silicone or H2S.
What’s included with the Gas Clip MGC-IR-PUMP
- MGC-IR-PUMP Gas Detector
- Charger
- 10′ Sampling Hose
- 10 Additional Filters
- 5 Hydrophobic and 5 Particulate Stainless Steel Diffusion Stone
- Callibration Certificate
- Quick Start Guide
Certifications & Approvals for MGC-IR-PUMP & MGC-P-PUMP
- CSA: C22.2 No. 157 and C22.2 152 (MGC-IR-PUMP only)
- Class I, Division 1, Group A, B, C, and D
- MGC-IR-PUMP: Class I, Zone 0, AEx ia IIC T4 Ga
- MGC-P-PUMP: Class I, Zone 1, AEx d ia IIC T4 Gb
- UL-913 and ANSI/ISA-S12.13.01
- IECEx: IECEx CSA 14.0029
- IEC 60079-0:2011, 60079-1:2007, 60079-11:2011
- MGC-IR-PUMP: Ex ia IIC T4 Ga
- MGC-P-PUMP: Ex d ia IIC T4 Gb
- ATEX: Sira 14ATEX2120
- EN60079-0:2012, 60079-1:2014, 60079-11:2012, 60079-26:2007
- MGC-IR-PUMP: CE ll 1 G Ex ia llC T4 Ga
- MGC-P-PUMP: CE ll 1 G Ex d ia llC T4 Gb
- InMetro: IEx 14.0326
- ABNT NBR IEC 60079-0:2013, ABNT NBR IEC 60079-1:2009,
- ABNT NBR IEC 60079-11:2013
- MGC-IR-PUMP: Ex ia llC T4 Ga
- MGC-P-PUMP: Ex d ia IIC T4 Gb